T-4005 (10-40kVA)

The i-power T-4005 is a three phase-in/single phase-out, true double conversion UPS system with DSP control and isolation transformer which guarantees consistent and quality electrical power to protect your critical applications. The T-4005 is designed with a wide input voltage range to handle voltage fluctuations and high accuracy output voltage to fail safe the equipment. It has 3/1 phase structure and 1+1 parallel redundant function that allows two UPS models to operate in parallel and as backup for each other.

The T-4005 consists of an isolated transformer and an advanced SMD design, which ensures outstanding stability and high reliability. By adapting to the latest IGBT inverter technology, the T-4005 is able offer excellent voltage switching characteristics during generator operation.

Product Highlights

  • Advanced SCR rectifier and IGBT inverter technology.
  • Wide input range from 160Vac to 280Vac.
  • Overall efficiency 85%.
  • DSP technology to guarantee high performance.
  • Output power factor 0.9.
  • Generator compatibility.
  • Full digitised non-master slave parallel redundancy technology.
  • User friendly and intuitive interface.
  • Large LCD screen with multi-functional keyboard.
  • MCU control to operate all power conversion sessions during operations.
  • Built-in output isolated transformer.
  • Optional SNMP card available.
  • Optional i-power Remote Management System (RMS) available.

Applications

  • Computer Network
  • Local Area Network
  • Work Stations
  • Servers
  • Banking
  • Security
  • Education
  • Emergency Devices
  • E-commerce
  • Elevator & Lifts
  • Healthcare
Order Code900-331900-332900-333900-334900-335
Capacity10KVA/9KW15KVA/13.5KW20KVA/18KW30KVA/27KW40KVA/36KW
INPUT
Input Voltage380Vac+N+W,3 phase
Input Voltage Range 285 ~ 475Vac
Input Frequency Range50Hz±5%
OUTPUT
Output Voltage220Vac+N+W,Single phase
Output Frequency 50Hz±0.1% ( BAT Mode )
Output PF0.9
Overall Efficiency (AC-AC)>85%
Output WaveformPure Sine Wave
Short-CircuitCircuit Auto Protection, Bypass Switch Tripping
Output AbnormalINV. Output Auto-Locked Protection
Static Bypass Transfer Time0ms
BATTERY
TypeSealed Lead Acid Maintenance Free
Battery Rated Volts/Unit360Vdc/30 Units
Charging current10-20 A
BAT LowShutdown Protection
PHYSICAL
Size mm(W*D*H) 310*675*850430*985*1030
Net Weight (kg)151162175295330
OTHERS
Working Temperature( ⁰C) -10-40
ProtectionsOverload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
DisplayLCD Display +LED Indicators
Cooling SystemIntelligent speed control cooling fan
Communication PortRs232/SNMP/485/ Dry Contact (Optional Accessory)
Remote Monitoring SoftwareMulti-functional Monitoring System,
Online and BAT Mode Status, BAT Fault, Remote Control
AlarmUtility Power Fault, BAT Voltage Low, Overload, PS Fault