T-4006 (10-40kVA)

The i-power T-4006 is a three phase-in/three phase-out true online double conversion UPS system with multi CPU, full digitised DSP control technology. It has parallel redundancy feature with isolation transformer, which ensures high reliability and stability. The T-4006 is designed with a wide input voltage range and 0.9 output power factor to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.

The T-4006 is available from 10kVA to 40kVA. By adopting the latest IGBT technology, this device is able to offer excellent voltage-switching characteristics during generator operation. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other.

Product Highlights

  • Advanced fifth generation IGBT inverter technology.
  • Wide input range from 285Vac – 475 Vac.
  • Overall system efficiency 90%.
  • DSP technology to guarantee high performance.
  • Full digital current control and non-prioritised parallel technologies.
  • Output power factor 0.9.
  • Generator compatibility.
  • Powerful overload ability with output short circuit protection technology.
  • User friendly and intuitive interface.
  • Intelligent charging management design (advance and flexible battery configuration, advance charging method, built-in BAT self-testing and diagnosis systems).
  • Intelligent fault diagnostic system with large storage memory.
  • Built-in output isolated transformer.
  • Multi communication interface integrated (RS232, RS485).
  • Large LCD touch screen with multi-functional buttons.
  • MCU control to operate all power conversion sessions during operations.
  • Built-in output isolated transformer.
  • Optional SNMP card available.
  • Optional i-power Remote Management System (RMS) available.

Applications

  • Datacentre
  • Telecom
  • Network management centres
  • Financial centres
  • Banking
  • Emergency devices
  • Industry
  • Airports
  • Healthcare
  • Elevator & Lifts
Order-code900-268900-269900-270900-271900-272
Capacity10KVA/9KW15KVA/13.5KW20KVA/18KW30KVA/27KW40KVA/36KW
INPUT
Input Voltage380Vac+N+W, (3-Phase + PE)
Input Voltage Range285-475Vdc
Input Frequency Range45-65Hz
Input PF0.95
Soft-Start>20 Seconds
THDI>5% (with optional accessories)
Input Current (A)2331405777
OUTPUT
Output VoltageLine Voltage: 380 x (1x1%) AC or Phase Voltage: 220 x (1x1%) AC
Overall Efficiency (AC-AC)0.9
Output Power Factor0.9
Output Voltage Regulation380Vac±1% (Static Load);380Vac±2% (50-0% Sudden Change);380Vac±3% (100-0% Sudden Change)
Output WaveformPure Sine Wave
Overload> 125%: More than 10 min;
> 150%: 60 ms transfer to bypass
Crest Ratio3:1
Efficiency>93%
Short-CircuitCircuit Auto Protection, Bypass Switch Tripping
Output AbnormalINV. Output Auto-Locked Protection
Static Bypass Transfer Time0ms
BATTERY
TypeSealed Lead Acid Maintenance Free
Rated Volts/Units (Vdc)12V/384Vdc, Std. for 32 Units,adjustable from 28-32 units
Abnormal ProtectionsBAT over-charged, Emergency charger shutdown protection or UPS shutdown protection
OTHERS
Working Temperature(⁰C) -10-40
ProtectionsOverload, Short-Circuit, Over Temp, Utility Power
Voltage High/low, BAT Voltage High/low
Display Multi-Language with all kinds of messages. Input Output Status, ECO Mode Settings, Display INV Temp. TX Status Calendar, Time, Serial Number, Model, Structure, History Logs, Battery Test. LED Indicators: UPS States Indicator
Cooling SystemIntelligent speed control cooling fan
Communication PortRs232/SNMP/485/ Dry Contact (Optional Accessory)
Remote Monitoring SoftwareMulti-functional Monitoring System, Online and BAT Mode Status,
BAT Fault, Remote Control
PHYSICAL
Size (W*D*H)470*1100*700520*1150*755
Net Weight (kg)210223230280330