T-6002 (20-40KVA)

The i-power T-6002 is a true double conversion modular structure online UPS system which guarantees consistent and quality electrical power to protect your mission critical applications such as small to medium datacentres, medical devices and telecommunication facilities. The
T-6002 offers parallel redundant features which can replace the 1+1 parallel UPS system with total harmonic distortion THDI ≤5%, output power factor 0.8, and overall efficiency AC-AC up to 94%, reducing the consumption of energy and the total cost of ownership.

The T-6002 is known for its high reliability, user friendly interface and remote-control system, ideal for medium to large data centres, precision equipment and telecom industry.

Product Highlights

  • Parallel redundancy module technology to increase system reliability.
  • Online Hot-Swap feature to reduce system maintenance cost.
  • Mean-Time-Between-Failures (MTBF) is 1.5 times longer than traditional UPS systems.
  • Designed with disk array concept and system modular redundancy.
  • Two-way information monitoring and self-diagnostic functions with intelligent monitoring software.
  • Advanced PFC circuit design.
  • Superior parallel ability, increasing the reliability of the UPS.
  • Low THDI ≤5% & high input power factor 0.99.
  • Integrates advanced power multi capacities and phase technology.
  • Optional i-power Remote Management System (RMS) available.
  • Optional SNMP card.

Applications

  • Small and medium critical load applications
  • Datacentres
  • Communication equipment
  • Precision instruments.
Order-code900-352
Capacity40KVA/32KW
Power Module 20KVA/16KW : Order code (900-353)
INPUT
Input Voltage380Vac+N+W, 3 Phase
Input Voltage Range380Vac+15% -25%(304-478Vac)
Input Frequency Range50Hz±5%
Input PF0.99
THDI<10%
Input Current (A)20KVA:N×3×15A, Starting without surge current
OUTPUT
Output VoltageLine Voltage: 380×(1±1%)AC or Phase Voltage: 220×(1±1%)AC
Output PF0.8
Overall Efficiency >94%
Output Frequency 50Hz±0.1% (BAT Mode)
when input or bypass frequency in more than ±8% or under BAT Mode
Distortion<2%(Linear Full Load),<3%(Non-Linear Full Load)
Output WaveformPure Sine Wave
Overload110%: More than 10 mins;
> 125%: More than 1 min;
> 150%: 30 ms transfer to bypass;
Crest Ratio3:1
Static Bypass Transfer Time0ms
Manual Maintenance BypassAvailable
BATTERY
TypeSealed Lead Acid Maintenance Free
Rated Volts/Units (Vdc)±360Vdc(±30 Units)
BAT LowShutdown protection
PHYSICAL
Module Size (W*D*H)440*590**131/3U
Cabinet Size (W*D*H)30U Cabinet:600×800×1516
Module Net Weight (kg)22
Cabinet Net Weight (kg)80
OTHERS
Working Temperature( ⁰C) 0-40
ProtectionsOverload, Shor t-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
Voltage High/low, BAT Voltage High/low
Display7 Inch LCD Color Touch Screen(multi-language with all kinds of messages)+LED
Cooling SystemIntelligent speed control cooling fan
Communication PortRs232/SNMP/485/ Dry Contact (Optional Accessory)
Remote Monitoring SoftwareMulti-functional Monitoring System, Online and BAT Mode Status,
BAT Fault, Remote Control