T-4111 1-In / 1-Out, Low frequency, without battery, 0.8 PF (1-10KVA)

The i-power T-4111 series is a true online double-conversion rackmount UPS that can provide your critical equipment with reliable and stable sine wave power. It features significant advantages, including an output power factor of 0.8 and up to 85% AC-AC efficiency for greater energy savings.

It is a versatile, high quality, and cost-competitive UPS developed to handle a wide voltage range and inconsistent power conditions. The T-4111 series provides a safe power supply guaranteed for mission-critical applications such as computer equipment, telecommunication devices, precision instrument, network termination equipment, and more.

Product Highlights:

  • Wide input voltage range; 160-280Vac.
  • Battery low/over charged sensor to protect the charger.
  • Advanced SCR rectifier and IGBT inverter technology.
  • Surge current protection technology to manage sudden impact of 0% to 100% load immediately without transfer to bypass.
  • Front to rear ventilation design to reduce the MTTR rate of the UPS.
ModelOL1001R80600SOL1002R80600SOL1003R80800SOL1006R81600S / OL1006R80800SOL1008R81600SOL1010R81600S
Capacity1KVA/0.8KW2KVA/1.6KW3KVA/2.4KW6KVA/4.8KW8KVA/6.4KW10KVA/8KW
Technical Specification
UPS StructureOnline Double Conversion
TopologyLow Frequency with Output Isolation Transformer
Overall Efficiency (AC-AC )> 85%
Noise(In 2 meters)< 50dB
Working Temp-10-40℃
Storage Temp-25 ~ 60℃(Without Batteries)
Humidity< 95%Non-Condensing
Safety StandardIEC62040
Parallel RedundancyAvailable
ProtectionsOverload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
DC StartAvailable
Generator CompatibilityAvailable
DisplayLCD Display
IP RatingIP20
Cooling SystemIntelligent Speed Control Cooling Fan
Elevation<1000M,Without Derating
Rectifier Specification
Input Voltage200/220/230/240Vac Single Phase
Input Voltage Range160-280Vac
Input Frequency Range50Hz±5%
Soft-Start> 20 Seconds
Output Specification
Output Voltage200/220/230/240Vac
Output PF0.8
Output Voltage Regulation220Vac±1%( Static Load ),220Vac±2%(50~0% Sudden Change)
Output Freq50Hz±0.1%(BAT Mode)
Distortion<1%(Linear Full Load),< 3%(Non-Linear Full Load)
Frequency Tracking Range46-54Hz
Output WaveformPure Sine Wave
Overload> 125%: More than 1 Min;
> 150%: More than 300ms
> 125%: More than 10 Mins;
> 150%: More than 1 Min
Noise SuppressionEMI/RFI Wave Filter
Crest Ratio3∶1
Short-CircuitCircuit Auto Protection,Output Voltage/Current 0
Output AbnormalINV. Output Auto-Locked Protection
Bypass Specification
Static Bypass Transfer Time0ms
Static Bypass Range220Vac(-15~+15%)
Frequency Range±1Hz, ±2Hz,±3Hz Adjustable
Bypass -> INV Transfer Time2ms
Frequency Tracking Speed0.5-2hz/s
Manual Maintenance BypassNoneAvailable
Alarm Specification
AlarmUtility Power Fault, BAT Voltage Low, Overload,UPS Fault
MuteAuto
Battery Specification
TypeSealed Lead Acid Maintenance Free
VDC72Vdc72Vdc96Vdc 192Vdc / 96Vdc192Vdc192Vdc
Charging Current5A - Standard 10A-Optional5A - Standard 10A-Optional5A - Standard 10A-Optional5A - Standard 10A-Optional5A - Standard 10A-Optional5A - Standard 10A-Optional
BAT LowShutdown Protection
Communication Specification
Standard Communication PortRs232
OptionalSNMP/RS485/ Dry Contact
Remote SoftwareMulti-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control
Physical Parameters
Dimensions in mm(W×D×H)430×580×178/4U430×580×220/6U430×600×266/8U
Net Weight (Kg)222329436270
Note: Specifications are subject to change without further notice.