The i-power “Static Voltage Stabilizers” provide protection against main power sags, surges and brownouts. It is ideal for locations that are subject to inconsistencies in the main supply. Each stabilizer has a wide input voltage tolerance and has been designed to provide the ultimate reliability in hostile environments where the quality of the main supply cannot be guaranteed.
The Non- contact voltage stabilizer series adopts the latest DSP operation control technology, fastest AC sampling, effective values calibrating, current zero-crossing switching and fast compensating voltage stabilizing technology to meet the new generation technology requirements. This product is extremely suitable for equipment that require highly reliable and stable power supply or environments where high amplitude of voltage fluctuation is common.
Product Highlights
- Non-contact based technology and free from abrasion & routine maintenance
- Multi Info LCD Display
- Precise output voltage regulation
- Fast response time against input voltage fluctuations
- Overload, Under/Over Voltage, Short Circuit, Bypass protection
- Adapts smart CPU control technology to control all processes to increase system reliability.
- All devices are fully tested and verified for maximum performance.
Application
- Telecom
- Medical
- Industrial
- Commercial
- Household appliances
Model |
T100523223S |
T101023223S |
T101523223S |
T102023223S |
T103023223S |
Power Rating (KVA) |
5KVA |
10KVA |
15KVA |
20KVA |
30KVA |
Technical Specifications |
Control Method |
SCR/Non-Contact (Microprocessor CPU) |
Input Rated Voltage |
1 x 230VAC (1Phase + N) |
Voltage Range |
230VC±20% (Optional: ±25,±30%) |
Frequency |
50/60 Hz |
Output Rated Voltage |
1 x 230VAC (1Phase + N) |
Stabilizing Accuracy |
±1~5% Adjustable |
Power Factor |
PF >= 0.8 |
Efficiency |
>= 98% |
Response time |
<= 0.5S |
Delay time |
<= 5s(Optional) |
Waveform Distortion |
<= 1% |
Over Voltage |
Power cut off in 3-5s if Output voltage >10% |
Under Voltage |
Power cut off in 3-5s if Output voltage < 15% |
Overload |
Power cut off in 3-5s |
Short Circuit |
Power cut off |
Manual Bypass |
Available |
Digital Display |
Real-time display of input/output voltage, output currents |
Working Status |
AVR, Bypass, Fuse Blown, Over-voltage, Under-voltage,Over-load |
Cooling System |
Air Cooled |
Insulation Resistance |
>= 2M Ohm |
Noise |
<65dB/m |
Ambient Temperature |
0°C-45°C ( No condensation ) |
Humidity |
20%-90% |
Size WxDxH (mm) |
280×550×300 |
350×600×400 |
Net Weight (KG) |
25kg |
30kg |
71kg |
85kg |
95kg |
Note: Product image and technical specifications are for reference and could be change without any notice. Custom built solutions are also available to meet specific requirements |