| Model |
OH1001T80300S |
OH1002T80600S |
OH1003T80800S |
OH1006T91600S |
OH1010T91600S |
| Capacity |
1KVA / 0.8KW |
2KVA / 1.6KW |
3KVA /2.4KW |
6KVA / 5.4KW |
10KVA / 9KW |
| Technical Specifications |
| UPS Structure |
Online Double Conversion - Tower Type |
| Topology |
High Frequency, Transformer Less |
| Overall Efficiency (AC-AC ) |
> 90% |
| Noise(In 2 Meters) |
< 55dB |
| Working Temp |
0-40℃ |
| Storage Temp |
-15 ~ 60℃(Without BATs) |
| Humidity |
< 95% Non Condensing |
| Safety Standard |
GB/T14715; EN62040-1 |
| EMC Standard |
EN 50091-1/2, EN62040-2 |
| Protections |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low |
| Generator Compatibility |
Available |
| DC Start |
Available |
| Manual Maintenance Bypass |
None |
Optional |
| Display |
LCD/LED |
| Alarm |
Auto |
| Mute |
Auto |
| ECO Mode |
Available |
| Rectifier Specification |
| Input Voltage Range |
110~300VAC ±5VAC (175-285VAC at full load) |
| Input Frequency Range |
40Hz to 70Hz (Auto Sensing) |
| Input PF |
0.99 |
| THDI |
< 5% |
| Output Specification |
| Output Voltage |
220Vac |
| Output PF |
0.8 |
0.9 |
| Output Voltage Regulation |
220Vac±1% (Static Load); 220Vac±2% (50-0% Sudden Change); 220Vac±3% (100-0% Sudden Change) |
| Output Freq. (BAT Mode) |
50Hz±0.2% |
| Output Waveform |
Pure Sine Wave |
| Distortion |
< 1%(Linear Full Load),< 3%(100% Non-Linear Load) |
| Overload |
105 - 125% for 1 Minute 126 - 150%for 30 seconds |
105 - 125% for 10 Minutes 126 - 150% for 1 Minute |
| Crest Ratio |
3:1 |
| Efficiency |
> 90% |
| Short-Circuit |
Circuit Auto Protection, Output Voltage/Current 0 |
| Output Abnormal |
INV Output Auto-Locked Protection |
| Noise Suppression |
EMI/RFI Wave Filter |
| BAT Low |
Shutdown Protection |
| Dynamic Response |
3% At Full Load,Recovering In 20ms |
| Auto-Restart |
Available |
| Software Control |
Available |
| Bypass Specification |
| Static Bypass Transfer Time |
0ms |
| Static Bypass Range |
80Vac± 5%~285Vac±5% |
| Bypass - INV Transfer Time |
2ms |
| Battery Specification |
| Model |
OH1001T80300S |
OH1002T80600S |
OH1003T800S |
OH1006T91600S |
OH1010T91600S |
| Capacity |
1KVA / 0.8KW |
2KVA / 1.6KW |
3KVA /2.4KW |
6KVA / 5.4KW |
10KVA / 9KW |
| Type |
Sealed Lead Acid Maintenance Free |
| VDC |
36 |
72 |
96 |
192 |
| Charging Current |
Max 4A |
Max 4A |
Max 4A |
Max 4A (10A Optional) |
| Communication Specification |
| Standard Communication Port |
Rs232 |
| Optional |
SNMP/RS485/ Dry Contact |
| Remote Software |
Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control |
| Physical Characteristics |
| Dimensions In mm |
145X220X248 |
145X220X318 |
190X318X368 |
190X340X528 |
| Net Weight Kg |
3.5 |
5.9 |
8.3 / 10 |
16 |
| Note: Product image and technical specifications are for reference and could be change without any notice. |