Model |
OH3010T81607S |
OH3020T82007S |
Capacity |
10KVA/8KW |
20KVA/16KW |
Technical Specification |
UPS Structure |
Online Double Conversion |
Topology |
High Frequency Online Design |
Overall Efficiency (AC-AC) |
> 91% |
Noise (In 2 Meters) |
< 60dB |
Working Temp. |
-10-40℃ |
Storage Temp. |
-25 ~ 6 0 ℃( Without Batteries) |
Humidity |
< 95% Non-Condesing |
International Standard |
EN 50091-1/2, EN62040-1,EN62040-2 |
Parallel Redundancy |
Parallel Redundancy Upto 8 Units |
Protection |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low |
DC Start |
Available |
Generator Compatibility |
Available |
Display |
LCD Display With Multi Information; Output Voltage Selectable:200/208/220/230/240, Output Frequency Selectable:0/50/60Hz; +LED ( Working Diagram) |
Mute |
Auto |
Cabinet Standard |
IP20 |
Cooling System |
Intelligent Speed Control Cooling Fan |
Elevation |
<1500M,Without Derated |
Rectifier Specification |
Input Voltage |
380Vac+N+W |
Input Voltage Range |
265-494Vac With 100% Full Load, No Load Can Reach 210-494Vac |
Input Frequency Range |
40-70Hz (Adjustable) |
Soft-Start |
> 20 Seconds |
Input PF |
0.99 |
THDI |
< 5% |
Output Specification |
Output Voltage |
Line Voltage: 380×(1±1%)AC Or Phase Voltage: 220×(1±1%)AC |
Output Power Factor |
0.8 |
Output Voltage Regulation |
380Vac±1%(Static Load); 380Vac ± 3%(50-0% Sudden Change); 380Vac±5% (100-0% Sudden Change) |
Output Frequency |
46-54Hz Sync With Utility Grid, More Than The Range Lock At 50Hz, Battery Mode Is 50/60Hz±0.1% |
Distortion |
< 1%(Linear Full Load),<3%(Non-Linear Full Load) |
3 Phase Unbalanced |
Allow 3 Phase 100% Unbalanced |
Output Volt Unbalanced Degree |
≤1%(Balanced Load); ≤2%(50% Balanced Load) |
Input/Output Phase Swift |
≤1°(Balanced Load); ≤2°(50% Balanced Load) |
Frequency Tracking Range |
46Hz to 54Hz |
Output Waveform |
Pure Sine Wave |
Overload |
105-125%±5% More Than 1 Minute;> 125-130%±5% More Than 30 Seconds;≥ 135%±5% More Than 300 Ms |
Crest Ratio |
3∶1 |
Short-Circuit |
Circuit Auto-Protection, Bypass Switch Tripping |
Output Abnormal |
INV. Output Auto-Locked Protection |
Bypass Specification |
Static Bypass Input Range |
380Vac(-15~+15%) |
Bypass - INV Transfer Time |
2ms |
Frequency Tracking Speed |
0.5-2hz/S |
Manual Maintenance Bypass |
Available |
Battery Specification |
Model |
OH2010T81600S |
OH2020T81600S |
Capacity |
10KVA / 8KW |
20KVA / 16KW |
Type |
Sealed Lead Acid Maintenance Free |
VDC - Ah |
192Vdc - 7Ah |
240Vdc - 7Ah |
Charging Current |
1 Amp |
BAT Low |
Shutdown Protection |
Communication Specification |
Standard Communication Port |
Rs232 |
Optional |
SNMP/RS485/ Dry Contact |
Remote Software |
Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control |
Physical Characteristics |
Dimensions (W×D×H) mm |
260×560×717 |
260×710×717 |
Net Weight (Kg) |
72 |
98 |
Note: Product image and technical specifications are for reference and could be change without any notice. |