Model |
OL1001T80607S |
OL1002T80607S |
OL1003T80807S |
OL1006T81607S |
Capacity |
1KVA/0.8KW |
2KVA/1.6KW |
3KVA/2.4KW |
6KVA/4.8KW |
Technical Specification |
UPS Structure |
Online Double Conversion |
Topology |
Low Frequency With Output Isolation Transformer |
Overall Efficiency (AC-AC ) |
> 85% |
Noise(In 2 Meters) |
< 50dB |
Working Temp |
-10-40℃ |
Storage Temp |
-25 ~ 60℃(Without Batteries) |
Humidity |
< 95%Non-Condensing |
Safety Standard |
IEC62040 |
Parallel Redundancy |
Available |
Protections |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low |
DC Start |
Available |
Generator Compatibility |
Available |
Display |
LCD Display |
Mute |
Auto |
IP Rating |
IP20 |
Cooling System |
Intelligent Speed Control Cooling Fan |
Elevation |
<1000M,Without Derating |
Rectifier Specification |
Input Voltage |
220/200/230/240Vac Single Phase |
Input Voltage Range |
160-280Vac |
Input Frequency Range |
50Hz±5% |
Soft-Start |
> 20 Seconds |
Output Specification |
Output Voltage |
220/200/230/240Vac |
Output PF |
0.8 |
Output Voltage Regulation |
220Vac±1%( Static Load ),220Vac±2%(50~0% Sudden Change) |
Output Freq |
50Hz±0.1%(BAT Mode) |
Distortion |
<1%(Linear Full Load),< 3%(Non-Linear Full Load) |
Frequency Tracking Range |
46-54Hz |
Output Waveform |
Pure Sine Wave |
Overload |
> 125%: More Than 1 Min; |
|
> 150%: More Than 300ms |
Noise Suppression |
EMI/RFI Wave Filter |
Crest Ratio |
3∶1 |
Short-Circuit |
Circuit Auto Protection Output Voltage/Current |
Output Abnormal |
INV. Output Auto-Locked Protection |
Bypass Specification |
Static Bypass Transfer Time |
0ms |
Static Bypass Range |
220Vac(-15~+15%) |
Frequency Range |
±1Hz, ±2Hz,±3Hz Adjustable |
Bypass - INV Transfer Time |
2ms |
Frequency Tracking Speed |
0.5-2hz/S |
Alarm Specification |
Alarm |
Utility Power Fault, BAT Voltage Low, Overload,UPS Fault |
Mute |
Auto |
Battery Specification |
Model |
OL1001T80607S |
OL1002T80607S |
OL1003T80807S |
OL1006T81607S |
Capacity |
1KVA/0.8KW |
2KVA/1.6KW |
3KVA/2.4KW |
6KVA/4.8KW |
Type |
Sealed Lead Acid Maintenance Free |
VDC - AH Rating |
72Vdc - 7Ah |
72Vdc - 7Ah |
96Vdc - 7Ah |
192Vdc - 7Ah |
Charging Current |
1A |
1A |
1A |
1A |
BAT Low |
Shutdown Protection |
Communication Specification |
Standard Communication Port |
Rs232 |
Optional |
SNMP/RS485/ Dry Contact |
Remote Software |
Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control |
Physical Characteristics |
Dimensions(W×D×H) Mm |
220×510×395 |
220×610×635 |
Net Weight (Kg) |
37.5 |
38.5 |
49 |
84 |
Note:Product Image And Technical Specifications Are For Reference And Could Be Change Without Any Notice. |