T-4102 TB 3-1 (0.8PF), Without battery (6-30KVA)

Call For Pricing

 

The i-power T-4102 series is a true online double-conversion UPS that can provide your critical equipment with reliable and stable sine wave power. It features significant advantages, including an output power factor of 0.8 and up to 98% AC-AC efficiency for greater energy savings.

It is a versatile, high quality, and cost-competitive UPS developed to handle a wide voltage range and inconsistent power conditions. The T-4102 series provides a safe power supply guaranteed for mission-critical applications such as computer equipment, telecommunication devices, precision instrument, network termination equipment, and more.

Product Highlights:

  • Wide Input Voltage Range; 3 Phase-In/1 Phase-out 380Vac ±25%.
  • High Efficiency 98% under ECO Mode.
  • Battery low/over charged sensor to protect the charger.
  • Advanced SCR rectifier and IGBT inverter technology.
  • Surge current protection technology to manage sudden impact of 0% to 100% load immediately without transfer to bypass.
  • Front to rear ventilation design to reduce the MTTR rate of the UPS.
Model OL2006T83200S OL2010T83200S OL2015T83200S OL2020T83200S OL2030T83200S
Capacity 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW
Technical Specification
UPS Structure Online Double Conversion
Topology Low Frequency With Output Isolation Transformer
Overall Efficiency (AC-AC ) > 85%
Noise(In 2 Meters) < 50dB
Working Temp -10-40℃
Storage Temp -25 ~60℃(Without Batteries)
Humidity < 95%Non-Condensing
Safety Standard IEC62040
Parallel Redundancy Available
Protections Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low
DC Start Available
Generator Compatibility Available
Display LCD
Mute Auto
IP Rating IP20
Cooling System Intelligent Speed Control Cooling Fan
Elevation <1000M,Without Derated
Rectifier Specification
Input Voltage 380Vac ±25% 3 Phase
Input Voltage Range 285-475Vac
Input Frequency Range 50Hz±5%
Soft-Start > 20 Seconds
Output Specification
Output Voltage 200/220/230/240Vac
Output PF 0.8
Output Voltage Regulation 220Vac±1% ( Static Load ), 220Vac±2% (50~0% Sudden Change)
Output Freq 50Hz±0.1%(BAT Mode)
Distortion <1%(Linear Full Load),< 3%(Non-Linear Full Load)
Frequency Tracking Range 46Hz - 54Hz
Output Waveform Pure Sine Wave
Overload > 125%: More Than 1 Min; > 150%: More Than 300ms
Noise Suppression EMI/RFI Wave Filter
Crest Ratio 3∶1
Short-Circuit Circuit Auto Protection,Output Voltage/Current 0
Output Abnormal INV. Output Auto-Locked Protection
Bypass Specification
Static Bypass Transfer Time 0ms
Static Bypass Range 220Vac(-15~+15%)
Frequency Range ±1Hz, ±2Hz, ±3Hz
Bypass - INV. Transfer Time 2ms
Frequency Tracking Speed 0.5hz - 2hz/S
Manual Maintenance Bypass None Available
Alarm Specification
Alarm Utility Power Fault, BAT Voltage Low, Overload,UPS Fault
Mute Auto
Battery Specification
Model OL2006T83200S OL2010T83200S OL2015T83200S OL2020T83200S OL2030T83200S
Capacity 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW
Type Sealed Lead Acid Maintenance Free
VDC 336-384Vdc
Charging Current 5-10A (Adjustable)
BAT Low Shutdown Protection
Communication And Specification
Standard Communication Port Rs232
Optional SNMP/RS485/ Dry Contact
Remote Software Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control
Physical Parameters
Dimensions In Mm(W×D×H) 220×610×715 310×670×820
Net Weight (Kg) 67 74 99 117 125
Note:Product image and technical specifications are for reference and could be change without any notice.