| Model |
OL3010T93200S |
OL3015T93200S |
OL3020T93200S |
OL3030T93200S |
OL3040T93200S |
| Capacity |
10KVA/9KW |
15KVA/13.5KW |
20KVA/18KW |
30KVA/27KW |
40KVA/36KW |
| Technical Specification |
| UPS Structure |
Online Double Conversion |
| Topology |
Low Frequency With Output Isolation Transformer |
| Overall Efficiency (AC-AC) |
0.9 |
| Noise (In 2 Meters) |
< 50-60dB |
| Working Temp. |
25 ~ 60℃ |
| Storage Temp. |
25 ~ 60℃ |
| Humidity |
< 95%, Non-Condensing |
| National Standard |
EN50091-1/IEC950 |
| International Standard |
EN 50091-1/2; EN62040-1; EN62040-2 |
| Parallel Redundancy |
Available Upto 8 Units |
| Protection |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low |
| ECO |
Available |
| EPO Function |
Available |
| DC Start |
Available |
| Generator Compatibility |
Available |
| Display |
LCD + LED |
| Mute |
Auto |
| IP Rating |
IP20 |
| Cooling System |
Intelligent Speed Control Cooling Fan |
| Elevation |
<1500M, Without Derated |
| Rectifier Specification |
| Input Voltage |
380Vac+N+W(3 Phase + PE) |
| Input Voltage Range |
285-475Vac |
| Input Frequency Range |
45-65Hz |
| Input PF |
0.95( With Input Filter) |
| THDI |
<5%(With Optional Accessories) |
| Dual Input Availability |
Available(Optional Accessories) |
| Input Mis Phase Protection |
Misphase Alarm, UPS Will Not Be Started |
| Input Phase Lost Protection |
Phase Lost Alarm, UPS Work On Bypass Mode |
| Soft-Start |
> 20 Seconds |
| Input Current |
23A |
31A |
39A |
54A |
70A |
| Output Specification |
| Output Voltage |
Line Voltage: 380×(1±1%)AC Or Phase Voltage: 220×(1±1%)AC |
| Output PF |
0.8/0.9 (No Lag) |
| Output Voltage Regulation |
380Vac±1%(Static Load);380Vac±2%(50-0% Sudden Change);380Vac±3%(100-0% Sudden Change) |
| Output Freq |
±8% At 50Hz: Online Mode Tracking Input And Bypass Freq.; ±0.1%: When Input Or Bypass Frequency Is More Than ±8% Or Under BAT Mode |
| THD |
< 1%(Linear Full Load),< 3%(Non-Linear Full Load) |
| 3 Phase Unbalanced |
Allow 3 Phase 100% Unbalanced |
| Output Volt. Unbalanced |
≤1°(Balanced Load); ≤2°(50% Balanced Load) |
| Input/Output Phase Swift |
≤1°(Balanced Load); ≤2°(50% Balanced Load) |
| Frequency Tracking Range |
45-65Hz |
| Output Waveform |
Pure Sine Wave |
| Overload |
>125%: More Than 10 Mins; > 150%: More Than 60s Transfer To Bypass |
| Crest Ratio |
3∶1 |
| Shor T-Circuit |
Circuit Auto-Protection, Bypass Switch Tripping |
| Output Abnormal |
INV. Output Auto-Locked Protection |
| Bypass Specification |
| Static Bypass Transfer Time |
0ms |
| Static Bypass Input Range |
380Vac(-15~+15%) |
| Frequency Range |
50/60Hz±1Hz, ±2Hz, ±3Hz Adjustable |
| Bypass - INV Transfer Time |
2ms |
| Frequency Tracking Speed |
0.5-2hz/S |
| Maintenance Bypass |
Available |
| Battery Specification |
| Model |
OL3010T93200S |
OL3015T93200S |
OL3020T93200S |
OL3030T93200S |
OL3040T93200S |
| Capacity |
10KVA/9KW |
15KVA/13.5KW |
20KVA/18KW |
30KVA/27KW |
40KVA/36KW |
| Charging Methods |
DSP Controlled Charger: Equalized/Pulse Charge, Float Charge, Intelligent Battery Management |
| Type |
Sealed Lead Acid Maintenance Free |
| VDC |
336-384VDC |
| Float Charge Voltage |
438Vdc |
| Charging Current |
5-10A |
| Abnormal Protections |
BAT Over-Charged, Emergency Charger Shutdown Protection Or UPS Shutdown Protection |
| Communication Specification |
| Standard Communication Port |
Rs232 |
| Optional |
SNMP/RS485/ Dry Contact |
| Remote Software |
Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control |
| Physical Characteristics |
| Size In Mm (W×H×D) |
475×990×700 |
550×1200×800 |
| Net Weight (Kg) |
210 |
223 |
230 |
280 |
330 |
| Note:Product image and technical specifications are for reference and could be change without any notice. |