| Model |
OL3060T93200S |
OL3080T93200S |
OL3100T93200S |
OL3120T93200S |
| Capacity |
60KVA / 54KW |
80KVA / 72KW |
100KVA / 90KW |
120KVA / 108KW |
| Technical Specification |
| UPS Structure |
Online Double Conversion |
| Topology |
Low Frequency With Output Isolation Transformer |
| Overall Efficiency (AC-AC ) |
> 85% |
| Noise(In 2 Meters) |
< 50dB |
| Working Temp |
-10 - 40℃ |
| Storage Temp |
-25 ~ 60℃(Without Batteries) |
| Humidity |
< 95%Non-Condensing |
| National Standard |
EN50091-1/IEC950 |
| International Standard |
EN 50091-1/2, EN62040-1, EN62040-2 |
| Parallel Redundancy |
Available upto 8 units |
| Protections |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low |
| ECO |
Available |
| EPO Function |
Available |
| DC Start |
Available |
| Generator Compatibility |
Available |
| Display |
LCD/LED |
| Mute |
Auto |
| IP Rating |
IP20 |
| Cooling System |
Intelligent Speed Control Cooling Fan |
| Elevation |
<1500M,Without Derating |
| Rectifier Specification |
| Input Voltage |
380Vac+N+W (3 Phase + PE) |
| Input Voltage Range |
285Vac to 475Vac |
| Input Frequency Range |
45Hz to 65Hz |
| Input Power Factor |
0.95 (with input filter) |
| THDI |
< 5% (with optional accessories) |
| Soft-Start |
> 20 Seconds |
| Dual Input Availability |
Available (optional accessories) |
| Input Mis Phase Protection |
Misphase Alarm, UPS will not be started |
| Input Phase lost Protection |
Phase Lost Alarm, UPS work on Bypass mode |
| Input Current |
100A |
125A |
160A |
192A |
| Output Specification |
| Output Voltage |
Line Voltage: 380×(1±1%) AC or Phase Voltage: 220×(1±1%) AC |
| Output Power Factor |
0.8/0.9 (No lag) |
| Output Voltage Regulation |
380Vac±1%(Static Load); 380Vac±2%(50-0% Sudden Change); 380Vac±3%(100-0% Sudden Change)) |
| Output Frequency |
±8% at 50Hz: Online Mode tracking input and bypass freq.; ±0.1%: when input or bypass frequency is more than ±8% or under BAT Mode |
| THDI |
< 1% (Linear Full Load), < 3% (Non-Linear Full Load) |
| 3 Phase Unbalanced |
Allow 3 Phase 100% Unbalanced |
| Output Volt. Unbalanced |
<= °(Balanced Load);<= 2°(50% Balanced Load) |
| Input/Output Phase Swift |
<= 1°(Balanced Load);<= 2°(50% Balanced Load) |
| Frequency Tracking Range |
45Hz to 65Hz |
| Output Waveform |
Pure Sine Wave |
| Overload |
> 125%: More Than 1O Min;> 150%: More than 60s transfer to bypass |
| Crest Ratio |
3∶1 |
| Short-Circuit |
Circuit Auto-Protection, Bypass Switch Tripping |
| Output Abnormal |
INV. Output Auto-Locked Protection |
| Bypass Specification |
| Static Bypass Transfer Time |
0ms |
| Static Bypass Input Range |
380Vac (-15 to+15%)) |
| Frequency Range |
50Hz to 60Hz ±1Hz, ±2Hz, ±3Hz Adjustable |
| Bypass - INV Transfer Time |
2ms |
| Frequency Tracking Speed |
0.5Hz to 2Hz/s |
| Manual Maintenance Bypass |
Available |
| Battery Specification |
| Model |
OL3060T93200S |
OL3080T93200S |
OL3100T93200S |
OL3120T93200S |
| Capacity |
60KVA / 54KW |
80KVA / 72KW |
100KVA / 90KW |
120KVA / 108KW |
| Charging Methods |
DSP Controlled Charger: Equalized/Pulse Charge, Float Charge, Intelligent Battery Management |
| Type |
Sealed Lead Acid Maintenance Free |
| VDC |
336VDC to 384VDC |
| Float Charge Voltage |
438Vdc |
| Charging Current |
5-10A |
| Abnormal Protections |
BAT Over-Charged, Emergency charger shutdown protection or UPS shutdown protection |
| Communication Specification |
| Standard Communication Port |
Rs232 |
| Optional |
SNMP/RS485/ Dry Contact |
| Remote Software |
Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control |
| Physical Characteristics |
| Dimensions(W×D×H) Mm |
605×1350×800 |
800×1600×800 |
| Net Weight (Kg) |
450 |
550 |
630 |
750 |
| Note:Product Image And Technical Specifications Are For Reference And Could Be Change Without Any Notice. |