| Model |
OL3160T93200S |
OL3200T93200S |
OL3250T93200S |
OL3300T93200S |
| Capacity |
160KVA/144KW |
200KVA/180KW |
250KVA/225KW |
300KVA/270KW |
| Model |
OL3400T93200S |
OL3500T93200S |
OL3600T93200S |
| Capacity |
400KVA/360KW |
500KVA/450KW |
600KVA/540KW |
| Technical Specification |
| UPS Structure |
Online Double Conversion |
| Toplogy |
Low Frequency With Output Isolation Transformer |
| Overall Efficiency (AC-AC) |
94%(With Optional Accessories) |
| ECO |
98% |
| Noise (In 2 Meters) |
67dB |
| Working Temp. |
0°C to 40°C |
| Storage Temp. |
15-50℃ |
| Humidity |
< 95% Non-Condensing |
| Standards |
IEC62040-2,IEC62040-3, IEC60950-1,IEC62040-1-1 |
| Parallel Redundancy |
Parallel Redundancy Upto 8 Units |
| Protection |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low |
| DC Start |
Available |
| Generator Compatibility |
Available |
| Display |
LCD |
| Mute |
Auto |
| IP Rating |
IP20 |
| Cooling System |
Intelligent Speed Control Cooling Fan |
| Elevation |
<1500M, Without Derating |
| Rectifier Specification |
| Input Voltage |
380/400/415Vac+N+W (3 Phase + PE) |
| Input Voltage Range |
298-498Vac |
| Input Frequency Range |
50/60Hz±10% |
| Soft-Start |
5-600 Seconds, Adjustable |
| Input PF |
0.95(With Optional Input Wave Filter) |
| THDI |
< 5%( With Optional Accessories) |
| Output Specification |
| Output Voltage |
Line Voltage: 380×(1±1%)AC Or Phase Voltage: 220×(1±1%)AC |
| Output PF |
0.9 |
| Output Voltage Regulation |
380Vac±1%(Static Load);380Vac±2%(50-0% Sudden Change);380Vac±3%(100-0% Sudden Change) |
| Voltage Dynamic Response |
±5%,(0~100% Sudden Change) |
| Voltage Dynamic Response Time |
<5ms |
| Synchronization Range |
±5% |
| Output Freq |
±0.02% (BAT Mode) |
| THD |
< 1%(Linear Full Load),< 3% (Non-Linear Full Load) |
| 3 Phase Unbalanced |
Allow 3 Phase 100% Unbalanced |
| Output Volt. Unbalanced |
≤1%( Balanced Load), ≤2%( 50% Balanced Load) |
| Input/Output Phase Swift |
≤1° (Balanced Load) , ≤2° (50% Balanced Load) |
| Frequency Tracking Range |
45Hz to 65Hz |
| Output Waveform |
Pure Sine Wave |
| Overload |
With Output PF 0.9, 105%: Long Time Operation,110%: 1 Hour,125%: 10 Mins,150%:1 Min |
| Crest Ratio |
3∶1 |
| Short-Circuit |
Circuit Auto-Protection, Bypass Switch Tripping |
| Output Abnormal |
INV. Output Auto-Locked Protection |
| Bypass Specification |
| Static Bypass Transfer Time |
0ms |
| Static Bypass Range |
380/400/415Vac(±10%,±15%,±20% Selectable)3 Phase+N(3 Phase+N+PE) |
| Frequency Range |
50/60Hz±10% |
| Bypass - INV Transfer Time |
2ms |
| Bypass Overload Ability |
200%: 5 Mins; 1000%:10 Seconds |
| Manual Maintenance Bypass |
Available |
| Battery Specification |
| Model |
OL3160T93200S |
OL3200T93200S |
OL3250T93200S |
OL3300T93200S |
| Capacity |
160KVA/144KW |
200KVA/180KW |
250KVA/225KW |
300KVA/270KW |
| Model |
OL3400T93200S |
OL3500T93200S |
OL3600T93200S |
| Capacity |
400KVA/360KW |
500KVA/450KW |
600KVA/540KW |
| Type |
Sealed Lead Acid Maintenance Free |
| VDC |
384VDC |
| Float Charge Voltage |
Equalized Charge, Float Charge, Intelligent Battery Management |
| Charging Current |
10-20A |
| BAT Low |
Shutdown Protection |
| Communication Specification |
| Standard Communication Port |
Rs232 |
| Optional |
SNMP/RS485/ Dry Contact |
| Remote Software |
Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control |
| Physical Parameters |
| Dimensions (DxHxW) |
855 X 1900 X 1245 |
855 X 1900 X 1640 |
855 X 1900 X 2265 |
855 X 1900 X 2615 |
| Net Weight (Kg) |
1075 |
1580 |
2105 |
2850 |
| Dimensions (DxHxW) |
955 X 1900 X 2865 |
| Net Weight (Kg) |
3130 |
| Note:Product image and technical specifications are for reference and could be change without any notice. |