| Model |
OH2010C81600S |
OH2015C81600S |
OH2020C81600S |
| Capacity |
10KVA/8KW |
15KVA/12KW |
20KVA/16KW |
| Model |
OH2010C92000S |
OH2015C92000S |
OH2020C92000S |
| Capacity |
10KVA/9KW |
15KVA/13.5KW |
20KVA/18KW |
| Host Machine Specification |
| UPS Structure |
Online Double Conversion |
| Topology |
High Frequency, Transformer Less |
| Overall Efficiency (AC-AC ) |
> 90% |
| Noise(In 2 Meters) |
< 50dB |
| Working Temp |
0-40℃ |
| Storage Temp |
-15 ~ 60℃(Without BATs) |
| Humidity |
< 95% Non Condensing |
| Safety Standard |
GB/T14715; EN62040-1 |
| EMC Standard |
EN 50091-1/2, EN62040-2 |
| Protections |
Overload, Short-Circuit, Over Temp., Utility Power Voltage High/Low, BAT Voltage High/Low |
| Generator Compatibility |
Available |
| DC Start |
Available |
| Manual Maintenance Bypass |
Optional |
| Display |
LCD/LED |
| Alarm |
Auto |
| Mute |
Auto |
| Rectifier Specification |
| Input Voltage Range |
304 ~ 478Vac |
| Input Frequency Range |
45-65Hz(Auto Tracking) |
| Input PF |
0.99 |
| THDI |
< 5% |
| Output Specification |
| Output Voltage |
220Vac |
| Output PF |
0.8/0.9 |
| Output Voltage Regulation |
220Vac±1%(Static Load);220Vac±2%(50-0% Sudden Change);220Vac±3%(100-0% Sudden Change) |
| Output Freq. (BAT Mode) |
50Hz± 0.2% |
| Output Waveform |
Pure Sine Wave |
| Distortion |
< 1%(Linear Full Load),< 3%(100% Non-Linear Load) |
| Overload |
> 120%: More Than 1 Min > 150%: 300ms Transfer To Bypass |
| Crest Ratio |
3∶1 |
| Efficiency |
> 90% |
| Short-Circuit |
Circuit Auto Protection, Output Voltage/Current 0 |
| Output Abnormal |
INV Output Auto-Locked Protection |
| Noise Suppression |
EMI/RFI Wave Filter |
| BAT Low |
Shutdown Protection |
| Dynamic Response |
3% At Full Load,Recovering In 20ms |
| Auto-Restart |
Available |
| Software Control |
Available |
| Bypass Specification |
| Static Bypass Transfer Time |
0ms |
| Static Bypass Range |
80Vac± 5%~285Vac±5% |
| Bypass - INV Transfer Time |
2ms |
| Battery Specification |
| Model |
OH2010C81600S |
OH2015C81600S |
OH2020C81600S |
| Capacity |
10KVA/8KW |
15KVA/12KW |
20KVA/16KW |
| Model |
OH2010C92000S |
OH2015C92000S |
OH2020C92000S |
| Capacity |
10KVA/9KW |
15KVA/13.5KW |
20KVA/18KW |
| Type |
Sealed Lead Acid Maintenance Free |
| VDC |
192/240Vdc |
192/240Vdc |
192/240Vdc |
| Charging Current |
5Amp |
5Amp |
5Amp |
| Communication Specification |
| Standard Communication Port |
Rs232 |
| Optional |
SNMP/RS485/ Dry Contact |
| Remote Software |
Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control |
| Physical Parameters |
| Dimensions In Mm (D×W×H) |
700×430×88/2U |
800×430×178/4U |
| Net Weight Kg |
25 |
35 |
35 |
| Note: Product Image And Technical Specifications Are For Reference And Could Be Change Without Any Notice. |