The i-power T-4011 series is a true online double-conversion Rack-Mountable UPS that can provide your critical equipment with reliable and stable pure sine wave power. . It has been designed for telecom standard with 48Vdc battery voltage. 1-3KVA with same height of 2U. It features significant advantages, including compatibility with Li-ion batteries.

Product Highlights:

  • Allows the UPS to work in harsh environments and reduces battery discharging time.
  • With output short circuit protection
  • To achieve high overall efficiency
  • 19’’ inch Rack Mount
  • Auto restart (when mains power is restored, after discharge of the batteries).
  • USB/RS232 & RJ-11/RJ45 serial port interface (Optional).
  • All devices are fully tested and verified for maximum performance.
Model OH1001R80400L OH1002R80400L OH1003R80400L
Capacity 1KVA/0.8KW 2KVA/1.6KW 3KVA/2.4KW
Technical Specification
UPS Structure Online Double Conversion - Rack Mountable Type
Topology High Frequency, Transformer Less
Overall Efficiency (AC-AC ) > 90%
Noise(In 2 Meters) < 50dB
Working Temp 0-40℃
Storage Temp -15 ~ 60℃(Without BATs)
Humidity < 95% Non Condensing
Safety Standard GB/T14715; EN62040-1
EMC Standard EN 50091-1/2, EN62040-2
Protections Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
Alarm Mains abnormal or Fault, BAT Voltage High/low, overload、UPS fault, shot circuit etc
Generator Compatibility Available
DC Start Available
Manual Maintenance Bypass Optional
Display LCD/LED: UPS Status, INV Status, Bypass Status, BAT Status, BAT %, Load %, Fault Messages
Alarm Auto
Mute Auto
Rectifier Specification
Input Voltage Range 100% Load:160~300Vac,50% Load:115~300Vac
Input Frequency Range 45-65Hz(Auto Tracking)
Input PF 0.99
THDI < 5%
Output Specification
Output Voltage 220Vac
Output PF 0.8
Output Voltage Regulation 220Vac±1%(Static Load);220Vac±2%(50-0% Sudden Change);220Vac±3%(100-0% Sudden Change)
Output Freq. (BAT Mode) 50Hz± 0.2%
Output Waveform Pure Sine Wave
Distortion < 1%(Linear Full Load),< 3%(100% Non-Linear Load)
Overload > 125%: More than 1 min
Crest Ratio 3∶1
Efficiency > 90%
Short-Circuit Circuit Auto Protection, Output Voltage/Current
Output Abnormal INV Output Auto-Locked Protection
Noise Suppression EMI/RFI Wave Filter
Battery Voltage Low Shut down protection
Dynamic Response 3% At Full Load,Recovering In 20ms
Auto-Restart function Available
Software Control Available
Bypass Specification
Static Bypass Transfer Time 0ms
Static Bypass Range 80Vac± 5%~285Vac±5%
Bypass - INV Transfer Time 2ms
Battery Specification
Type LiFePO4
VDC 48
Charging Current 5 A
Communication Specification
Standard Communication Port Rs232
Optional SNMP/RS485/ Dry Contact
Remote Software Multi-Functional Monitoring System, Online And BAT Mode Status, BAT Fault, Remote Control
Physical Specification
Dimensions In Mm (D×W×H) 320×430×88 - 2U 450×430×88 - 2U
Net Weight (Kg) 7.5 10.0 14.0
Note: Product images may differ from original product & specifications are subject to change without further notice.